For plate size 52 x 80 in (132 x 203 cm).
This combined Light Finishing and Post-exposure unit is equipped with electronic
ballasts only. Both light finisher and post exposure can operate at same time,
or separately (in both ways, finisher or post exposition first) in automatic mode.
Lamp temperature control and regulation, automatic defective lamp detection,
are new features available in this unit
Electronic ballasts
There are 45 UVC 60 W lamps, and 46 UVA 80 W lamps. All are fitted with electronic
ballast for a consistent and uniform Ultra Violet output onto the whole size of
the plates. Electronic ballast allows also a longer lamp life.
UVA and UVC
This unit is equipped with UVC and UVA lamps for the detacking and the final
polymerization of the plate. Both can be operated at the same time, or both
can be operated separately first or second.
Safety controls
Each lamp is equipped with an individual sensor for functioning control. A message
alarm (with the lamp number) appears automatically on the control panel display in
case a lamp is defective. Sensors for temperature control, for drawer opening
control complete the safety environment of this unit.
Exhaust
Two powerful blowers at the back of the unit and a special designed drawer front
panel provide efficient air replenishment in the whole drawer, as well as an
efficient fume exhaust. The unit is delivered with flexible air piping for the
connection of these blowers.
Technical data: Light Finisher 5280
- Dimensions (W x L x H): 295 x 202x 28 cm (116 x 80 x 11 inches)
- Weight: 380 Kg
- Power supply: 400V 3Ph/N/Pe 50/60Hz 7,5Kw 12A 230V 3Ph/N/Pe 50/60Hz 7,5Kw 20A
- Plate size: Up to 52 x 80 in (1 320 x 2 032 mm)
- Plate thickness: Up to 2.76 (7mm)
- Compressed air: Not needed
- Lamps: 45 UVC 75w + 46 UVA 80w 10R
- Crate dimensions: 320 x 230 x 113 cm (126 x 91 x 44 in)
- Crate weight: 740 Kg
- Crate dimensions Dryer+LF: 320 x 230 x 184 cm (126 x 91 x 72 in)
- Crate weight Dryer+LF: 1 720 Kg